The underfloor heating installation will be designed and installed by specialist underfloor heating contractor with no joins in the pipework under the floor. The system will comprise of 17mm Ambiente underfloor heating pipe with integral oxygen barrier and a 2mm wall thickness, secured to 'x'mm thick laminated Ambiente insulation panels laid on a concrete sub floor. Pipe to terminate at Ambiente underfloor heating manifold assembly complete with pumps, mixing valves, drain and fill points, air vents etc. at pre-arranged locations shown on drawings. The system is to be filled and pressure tested upon completion and left pressurised during screeding. Room thermostats, wiring centre and thermoelectric actuators are provided, the underfloor heating installation terminates at valved manifold connections; others to make appropriate connections from this point.
|
The underfloor heating installation will be designed and installed by specialist underfloor heating contractor with no joins in the pipework under the floor. The system will comprise of 17mm Ambiente underfloor heating pipe with integral oxygen barrier and a 2mm wall thickness, secured in plastic cliprails which are stapled to insulation laid on a concrete sub floor. Pipe to terminate at Ambiente underfloor heating manifold assembly complete with pumps, mixing valves, drain and fill points, air vents etc. at pre-arranged locations shown on drawings. The system is to be filled and pressure tested upon completion and left pressurised during screeding. Room thermostats, wiring centre and thermoelectric actuators are provided, the underfloor heating installation terminates at valved manifold connections; others to make appropriate connections from this point.
|